Technical Parameters

Model

PR9112 Intelligent Pressura Calibrator

Pressura mensurae

Mensuratio dolor

-0.1~250)Mpa

Propono accurate

±0.05%FS, ±0.02%FS

Electric Current mensurae

Range

±30.0000mA

Sensibilitas

0.1uA

Sagacitas

±(0.01%R.D+0.003%FS)

Voltage Mensuratio

Range

±30.0000V

Sensibilitas

0.1mV

Sagacitas

±(0.01%RD +0.003%FS)

Switching Value

Coetus Power / eu measurement

Munus output

Direct-current output

DC24V±0.5V

Operans Environmental

Operatio Temperature

-20~50)℃

Relativum Temperature

<95%

Repono Temperature

-30~80)℃

Virtus Supple configurationis

Potentia copia modus

Lithium altilium seu potentia copia

Pugna Operating Tempus

LX horis (24V cum sine onere)

dato tempore

De IV horas

Aliis indicibus

Magnitudo

115mm×45mm×180mm

Communicationis interface

specialized three-core aviation plug

Pondus

0.8KG

Praecipua Application:

1.Calibrate pressura (differentiae pressura) transfusor

2.Calibrate pressura switch

3. Verificare pressionem pressionem METIOR, Generalis pressura METIOR.

Product Feature:

1.Built-in munus operantis manualis, Cervus pressura intelligentis transfusor calibrari potest.

2.Double-row liquidum crystallum cum backlight ostentationem.

3.mmH2O、mmHg、psi、kPa、MPa、Pa、mbar、bar、kgf/c㎡, commutandum inter novem pressiones unitates.

4.With DC24V output munus.

5. With current, voltage measurement.

6.Measuring cum commutatione volumine.

7.With communicationis interface. (libitum)

8. Repono facultatem: totalis fasciculus XXX quam at pede, (50 data monumenta cuiusque fasciculi)

9.Big screen crystallum liquidum ostentationem

Software configurationis:

PR9112S programmata pressionis verificationis systematis est fulcra programmatio pressionis digitalis calibratoris in nostro comitatu productorum seriei, Data collectionis monumenta perfici possunt, forma auto- generata, error calculi automaticus, certificatorium Print.

1.Exercitatione Pressure dolor Electio Tabula

Nec.

Pressura dolor

Type

Genus accurationis

01

(-100~0) kPa

G

0.02/0.05

02

(0~60) Pa

G

0.2/0.05

03

(0~250)Pa

G

0.2/0.05

04

(0~1) kPa

G

0.05/0.1

05

(0 ~ 2) kPa

G

0.05/0.1

06

(0 ~ 2.5) kPa

G

0.05/0.1

07

(0~5) kPa

G

0.05/0.1

08

(0 ~ 10) kPa

G

0.05/0.1

09

(0 ~ 16) kPa

G

0.05/0.1

10

(0 ~ 25) kPa

G

0.05/0.1

11

(0 ~ 40) kPa

G

0.05/0.1

12

(0 ~ 60) kPa

G

0.05/0.1

13

(0 ~ 100) kPa

G

0.05/0.1

14

(0 ~ 160) kPa

G/L

0.02/0.05

15

(0 ~ 250) kPa

G/L

0.02/0.05

16

(0 ~ 400) kPa

G/L

0.02/0.05

17

(0 ~ 600) kPa

G/L

0.02/0.05

18

(0~1) MPa

G/L

0.02/0.05

19

(0 ~ 1.6) MPa

G/L

0.02/0.05

20

(0 ~ 2.5) MPa

G/L

0.02/0.05

21

(0~4) MPa

G/L

0.02/0.05

22

(0 ~ 6) MPa

G/L

0.02/0.05

23

(0 ~ 10) MPa

G/L

0.02/0.05

24

(0 ~ 16) MPa

G/L

0.02/0.05

25

(0 ~ 25) MPa

G/L

0.02/0.05

26

(0 ~ 40) MPa

G/L

0.02/0.05

27

(0 ~ 60) MPa

G/L

0.05/0.1

28

(0 ~ 100) MPa

G/L

0.05/0.1

29

(0 ~ 160) MPa

G/L

0.05/0.1

30

(0~ 250) MPa

G/L

0.05/0.1

Dicta: G=GasL=Liquid

2.Composita Pressure Range Electio Mensa:

Nec.

Pressura dolor

Type

Genus accurationis

01

±60 Pa

G

0.2/0.5

02

±160 Pa

G

0.2/0.5

03

± 250 Pa

G

0.2/0.5

04

±500 Pa

G

0.2/0.5

05

±1kPa

G

0.05/0.1

06

±2kPa

G

0.05/0.1

07

±2.5 kPa

G

0.05/0.1

08

±5kPa

G

0.05/0.1

09

±10kPa

G

0.05/0.1

10

±16kPa

G

0.05/0.1

11

±25kPa

G

0.05/0.1

12

±40kPa

G

0.05/0.1

13

±60kPa

G

0.05/0.1

14

±100kPa

G

0.02/0.05

15

(-100 ~160) kPa

G/L

0.02/0.05

16

(-100 ~ 250) kPa

G/L

0.02/0.05

17

(-100 ~ 400) kPa

G/L

0.02/0.05

18

(-100 ~600) kPa

G/L

0.02/0.05

19

(-0.1~1) Mpa

G/L

0.02/0.05

20

(-0.1~1.6) Mpa

G/L

0.02/0.05

21

(-0.1~2.5) Mpa

G/L

0.02/0.05

Ariovisto:

1.Partial range potest absolute facere pressura

2.Automatic temperatus excambium range:(-20~50℃)

3.Pressure translationem medium requirit non-mordax


  • Priora:
  • Deinde: