PR9112 Calibrator Pressurae Intelligens

Descriptio Brevis:

Novi generis producta (pacto HART adferri potest), ostentus crystalli liquidi duplicis ordinis cum illuminatione posteriori, novem unitates pressionis secundum necessitates reales utentium commutari possunt, cum functione egressus DC24V, cum variis stressoribus coniungi, et ad usum in agro et laboratorio aptissima.


Detalia Producti

Etiquettae Productarum

Parametri Technici

Modellum PR9112Calibrator Pressionis Intelligens
Mensura Pressionis Spatium Mensurae (-0.1~250)Mpa
Accuratio ostentationis ±0.05% FS, ±0.02% FS
Mensura Currentis Electrici Spatium ±30.0000mA
Sensibilitatem 0.1µA
Accuratio ± (0.01% R.D + 0.003% FS)
Mensura Tensionis Spatium ±30.0000V
Sensibilitatem 0.1mV
Accuratio ± (0.01% RD + 0.003% FS)
Valor Commutans Grex mensurarum potentiae/interruptionis
Functio emissionis Egressus currentis continui DC24V±0.5V
Operandi Ambitus Temperatura Operativa (-20~50)℃
Temperatura Relativa <95%
Temperatura Reponendi (-30~80)℃
Configuratio Fontis Electrici Modus alimentationis electricae Accumulator lithii vel fons potentiae
Tempus Operationis Batteriae Horae LX (24V sine onere)
Tempus impletionis Circiter quattuor horas
Alia indicia Magnitudo 115mm × 45mm × 180mm
Interfacies communicationis obturaculum aviationis trium filorum specializatum
Pondus 0.8 kg

Applicatio Praecipua:

1. Transmissorem pressionis (pressionis differentialis) calibrare

2. Pressostat calibrare

3. Manometrum accuratum, manometrum generalem, verifica.

Proprietas Producti:

1. Functio operatoris manualis inclusa, transmissor pressionis intelligens HART calibrari potest (ad libitum).

2. Ostentus crystalli liquidi duplicis ordinis cum illuminatione posteriori.

3. mmH2O, mmHg, psi, kPa, MPa, Pa, mbar, bar, kgf/c㎡, inter novem unitates pressionis commuta.

4. Cum functione egressus DC24V.

5. Cum mensura currentis et tensionis.

6. Mensura cum volumine commutante.

7. Cum interfacie communicationis (ad libitum)

8. Capacitas repositionis: summa fasciculi 30, (singulorum fasciculorum 50 inscriptiones datorum)

9. Magnum velum crystallinum liquidum ostentat

Configuratio Programmatum:

Programma PR9112S systematis verificationis pressionis est programmatum adiuvans systematis nostri digitalis.calibrator pressionisSeries productorum in societate nostra, acta collectionis datorum fieri possunt, forma automatice generata, computatio errorum automatica, impressio certificati.

1.Tabula Selectionis Intervalli Pressionis Ordinariae

Non. Ambitus Pressionis Typus Classis accurationis
01 (-100~0) kPa G 0.02/0.05
02 (0~60)Pa G 0.2/0.05
03 (0~250)Pa G 0.2/0.05
04 (0 ~ 1) kPa G 0.05/0.1
05 (0 ~ 2) kPa G 0.05/0.1
06 (0 ~ 2.5) kPa G 0.05/0.1
07 (0 ~ 5) kPa G 0.05/0.1
08 (0 ~ 10) kPa G 0.05/0.1
09 (0 ~ 16) kPa G 0.05/0.1
10 (0 ~ 25) kPa G 0.05/0.1
11 (0 ~ 40) kPa G 0.05/0.1
12 (0 ~ 60) kPa G 0.05/0.1
13 (0 ~ 100) kPa G 0.05/0.1
14 (0 ~ 160) kPa Generalis Litterarum 0.02/0.05
15 (0 ~ 250) kPa Generalis Litterarum 0.02/0.05
16 (0 ~ 400) kPa Generalis Litterarum 0.02/0.05
17 (0 ~ 600) kPa Generalis Litterarum 0.02/0.05
18 (0 ~ 1) MPa Generalis Litterarum 0.02/0.05
19 (0 ~ 1.6) MPa Generalis Litterarum 0.02/0.05
20 (0 ~ 2.5) MPa Generalis Litterarum 0.02/0.05
21 (0 ~ 4) MPa Generalis Litterarum 0.02/0.05
22 (0 ~ 6) MPa Generalis Litterarum 0.02/0.05
23 (0 ~ 10) MPa Generalis Litterarum 0.02/0.05
24 (0 ~ 16) MPa Generalis Litterarum 0.02/0.05
25 (0 ~ 25) MPa Generalis Litterarum 0.02/0.05
26 (0 ~ 40) MPa Generalis Litterarum 0.02/0.05
27 (0 ~ 60) MPa Generalis Litterarum 0.05/0.1
28 (0 ~ 100) MPa Generalis Litterarum 0.05/0.1
29 (0 ~ 160) MPa Generalis Litterarum 0.05/0.1
30 (0 ~ 250) MPa Generalis Litterarum 0.05/0.1

Adnotationes: G = Gas L = Liquidum

 

2.Tabula Selectionis Intervalli Pressionis Compositae:

Non. Ambitus Pressionis Typus Classis accurationis
01 ±60 Pa G 0.2/0.5
02 ±160 Pa G 0.2/0.5
03 ±250 Pa G 0.2/0.5
04 ±500 Pa G 0.2/0.5
05 ±1kPa G 0.05/0.1
06 ±2kPa G 0.05/0.1
07 ±2.5 kPa G 0.05/0.1
08 ±5kPa G 0.05/0.1
09 ±10kPa G 0.05/0.1
10 ±16kPa G 0.05/0.1
11 ±25kPa G 0.05/0.1
12 ±40kPa G 0.05/0.1
13 ±60kPa G 0.05/0.1
14 ±100kPa G 0.02/0.05
15 (-100 ~160) kPa Generalis Litterarum 0.02/0.05
16 (-100 ~250) kPa Generalis Litterarum 0.02/0.05
17 (-100 ~400) kPa Generalis Litterarum 0.02/0.05
18 (-100 ~600) kPa Generalis Litterarum 0.02/0.05
19 (-0.1~1)Mpa Generalis Litterarum 0.02/0.05
20 (-0.1~1.6)Mpa Generalis Litterarum 0.02/0.05
21 (-0.1~2.5)Mpa Generalis Litterarum 0.02/0.05

Adnotationes:

1. Spatium partiale pressionem omnino facere potest

2. Spatium compensationis temperaturae automaticae: (-20~50℃)

3. Medium translationis pressionis requirit non corrosivum

Sarcinatio


  • Praecedens:
  • Deinde: